Display: 18 mm LCD, 3 1/2 digits
Function:
dB (A & C frequency weighting)
Time weighting (Fast=200ms / Slow=500ms)
Max. hold, AC output, DC output
Measurement range: 3 ranges: 35 to 130 dB (typical 30 to 130 dB), input signal only
Resolution: 0.1 dB
Accuracy (23 ± 5°C):
Frequency weighting meet IEC 651 type 2, calibrating input signal on 94 dB (31.5 Hz to 8 kHz), then
the accuracy of A weighting is specified as following:
31.5Hz 63Hz 125Hz 250Hz 500 Hz 1kHz 1kHz 2kHz 4kHz 8kHz
±3dB ±2dB ±1.5dB ±1.5dB ±1.5dB ±1.5dB ±1.5dB ±2dB ±3dB ±5dB
Frequency weighting
network:
A weighting: The characteristic is simulated as "Human Ear Listing" response. Typical, if making the
environmental sound level measurement, always select to A weighting.
C weighting: The characteristic is near the "Flat" response. Typical, it is suitable for checking the noise
of machinery (Q.C. check) & knowing the sound pressure level of the tested equipment.
Frequency: 31.5 Hz to 8,000 Hz
Calibrator: B & K (Bruel & k multi-function acoustic calibrator, model: 4226)
Microphone: electric condenser microphone
Size of microphone: 1/2 inch standard size
Range selector:
30 to 80 dB
50 to 100 dB
80 to 130 dB
50 dB on each step, with over & under range indicating
Time weighting:
(Fast & Slow)
Fast: t=200 ms ("Fast" range is simulated the human ear response time weighting)
Slow: t=500 ms ("Slow" range is easy to get the average values of vibration sound level)
Out terminal: 3.5 phone output terminal is provided for connection with analyzer, level recorder, tape recorder
Output signal:
AC output - AC 0.5 Vrms corresponding to each range step
DC output - DC 0.3 to 1.3VDC; 10 mV per dB
Output impedance: 600 Ohm
Calibration: Built-in external calibration VR, easy to calibrate by external screw driver
Internal oscillation system, 1 kHz sine wave generator
Operating temp.: 0°C to 50°C (32°F to 122°F)
Operating humidity: max. 90% RH (0 to 35°C)
Power supply: 006P DC 9V battery (heavy duty type)
Power consumption: approx. DC 6 mA
Dimension: 205 x 80 x 35 mm (8.1 x 3.2 x 1.4 inch)
Weight: 250 gr. including battery
Display: 18 mm LCD, 3 1/2 digits
Function:
dB (A & C frequency weighting)
Time weighting (Fast=200ms / Slow=500ms)
Max. hold, AC output, DC output
Measurement range: 3 ranges: 35 to 130 dB (typical 30 to 130 dB), input signal only
Resolution: 0.1 dB
Accuracy (23 ± 5°C):
Frequency weighting meet IEC 651 type 2, calibrating input signal on 94 dB (31.5 Hz to 8 kHz), then
the accuracy of A weighting is specified as following:
31.5Hz 63Hz 125Hz 250Hz 500 Hz 1kHz 1kHz 2kHz 4kHz 8kHz
±3dB ±2dB ±1.5dB ±1.5dB ±1.5dB ±1.5dB ±1.5dB ±2dB ±3dB ±5dB
Frequency weighting
network:
A weighting: The characteristic is simulated as "Human Ear Listing" response. Typical, if making the
environmental sound level measurement, always select to A weighting.
C weighting: The characteristic is near the "Flat" response. Typical, it is suitable for checking the noise
of machinery (Q.C. check) & knowing the sound pressure level of the tested equipment.
Frequency: 31.5 Hz to 8,000 Hz
Calibrator: B & K (Bruel & k multi-function acoustic calibrator, model: 4226)
Microphone: electric condenser microphone
Size of microphone: 1/2 inch standard size
Range selector:
30 to 80 dB
50 to 100 dB
80 to 130 dB
50 dB on each step, with over & under range indicating
Time weighting:
(Fast & Slow)
Fast: t=200 ms ("Fast" range is simulated the human ear response time weighting)
Slow: t=500 ms ("Slow" range is easy to get the average values of vibration sound level)
Out terminal: 3.5 phone output terminal is provided for connection with analyzer, level recorder, tape recorder
Output signal:
AC output - AC 0.5 Vrms corresponding to each range step
DC output - DC 0.3 to 1.3VDC; 10 mV per dB
Output impedance: 600 Ohm
Calibration: Built-in external calibration VR, easy to calibrate by external screw driver
Internal oscillation system, 1 kHz sine wave generator
Operating temp.: 0°C to 50°C (32°F to 122°F)
Operating humidity: max. 90% RH (0 to 35°C)
Power supply: 006P DC 9V battery (heavy duty type)
Power consumption: approx. DC 6 mA
Dimension: 205 x 80 x 35 mm (8.1 x 3.2 x 1.4 inch)
Weight: 250 gr. including battery
Zoekertjesnummer: m2262849901
Populaire zoektermen
Meetapparatuurtesto meetapparatuurmeetapparatuurleica meetapparatuurmeetapparatuur elektriciteitelektronische meetapparatuurmeetapparatuur flukeelektronica meetapparatuurtesto meetapparatuurtesto meetapparatuurphilips meetapparatuurwaterpas 2 meterelektronische meetapparatuuroude meetapparatuurvelgen nissan qashqai in Banden en Velgenallerlei in Rommelmarktspullenaudi a4 b9 interieur in Interieur en Bekledingtv cassette in Overige Audio, Tv en Fotolinea raffaelli nieuw in Gelegenheidskledingvelgen zwijndrecht in Banden en Velgenbburago in Modelauto's | 1:18pups halen in Honden-accessoiresmercedes benz clc in Mercedes-Benzhonden golden retriever in Honden | Retrievers, Spani�ls en Waterhonden