HYD3000-ES Sofar hybrid inverter 3.0 kW/ 3.0 kVA 1 phase

€ 806,65
Ophalen of Verzenden
Verzenden voor € 5,95
551sinds 30 jan. '24, 15:29
Deel via
of

Beschrijving

Sofar HYD3000-ES single-phase energy storage intergrated inverter 3.0 kW/3.0 kVA (new but the box is open)   Battery Input Data Battery type Lithium-ion, Lead-acid Rated battery voltage (V) 48 Battery voltage range (V) 42 – 58 Battery capacity (Ah) 50 – 2000 Max. charging / discharging power (W) 3000 Max. charging current (A) 65 (programmable) Max. discharging current (A) 70 (programmable) Charging curve (Lithium-ion) BMS Charging curve (Lead-acid) 3-Stage adaptive with maintenance Depth of discharge Lithium-ion: 0 – 90% DOD adjustable, Lead-acid: 0 – 50% DOD adjustable Input DC (PV side) Recommended max. PV input power (Wp) 3990 Max. DC power for single MPPT (W) 2000 Max. input voltage (V) 600 Start-up voltage (V) 120 Rated DC voltage (V) 360 MPPT operating voltage range (V) 90 – 580 Full power MPPT voltage range (V) 160 – 520 MPPT number 2 Max. DC input current (A) 12 / 12 Max. DC input short current (A) 15 / 15 Output AC (Grid side)   Max. output power (W) 3000 Max. output current (A) 13,7 Rated grid voltage L / N / PE, 230 Vac Operation phase Single (L-N-PE) AC voltage range (V) 180 – 276 (according to local standard) Grid frequency range 44 – 55 Hz / 55 – 65 Hz (according to local standard) THD < 3% Power factor 1 default (+/-0.8 adjustable) Output AC (Emergency Power Supply)   EPS rated power (VA) 3000 Operation phase Single (L-N-PE) EPS rated voltage, frequency 230 V, 50 / 60 Hz EPS rated current (A) 13,2 Peak output apparent power (VA, s) 4000, 10 THD < 3% Switch time 10 ms default Efficiency MPPT efficiency 99,9% Max efficiency of solar inverter 97,6% European efficiency of solar inverter 97,2% Max. charging efficiency of battery 94,6% Max. discharging efficiency of battery 94,6% Protection PV reverse polarity protection Yes PV insulation detection Yes Ground fault monitoring Yes Overcurrent protection Yes Overvoltage protection Yes Battery soft start protection Yes DC-Switch Optional SPD protection III General Data   Ambient temperature range -25 – 60 (above 45 derating) Standby losses (W) < 10 Topology High frequency insolation (for battery) Degree of protection IP65 Allowable relative humidity range 0 – 100% Communication RS485 / WiFi / Ethernet / SD / CAN2.0 Protective class Class I Max. operating altitude 2000 m Current sensor connection External Noise <25 dB Weight (kg) 20,5 Cooling Natural Dimension (mm) 566*394*173 Display LCD Certifications & Standards   EMC EN 61000-6-2, EN 61000-6-3, EN 61000-3-2, EN 61000-3-3, EN 61000-3-11, EN 61000-3-12 Safety IEC 62109-1 / 2, IEC62040-1, IEC 62116, IEC 61727, IEC 61683, IEC 60068 (1, 2, 14, 30) Grid VDE V 0124-100, V 0126-1-1, VDE-AR-N 4105, CEI 0-21, EN 50549, G83 / G59 / G98 / G99, UTE C15-712-1, UNE 206 007-1

Zoekertjesnummer: a136776317